EICR Example: A Comprehensive Guide to Understanding an Electrical Installation Condition Report
If you’re searching for an “EICR example” to understand what an Electrical Installation Condition Report looks like and what it contains, you’re in the right place. As an expert in electrical safety, I want to provide a detailed explanation of what you can expect in an EICR, why it’s important, and how it helps in ensuring the safety of your property.
What is an EICR?
An Electrical Installation Condition Report (EICR) is a formal document that is produced following a thorough inspection of an electrical installation within a property. This inspection is carried out by a qualified electrician or approved contractor. The primary purpose of the EICR is to assess the safety and condition of the electrical installation and to identify any defects or potential hazards.
Below, we provide a detailed EICR example by breaking down each section of the report.
EICR Example: Key Sections Explained
To give you a better understanding, let’s go through an example of an EICR by looking at each section it contains. This will help you know what to expect when you receive your own EICR.
Section A: Details of the Client and Installation Address
In this section of the EICR example, you’ll find the basic information about the client requesting the report and the address where the electrical installation is located. This is essential for clearly identifying the property being assessed.
Section B: Reason for producing the report
This section of the EICR explains the specific reason or purpose for carrying out the inspection and generating the report. It is important because the condition of an electrical installation should be assessed at different stages, depending on the circumstances. Common reasons include:
- Routine Inspection: To ensure the installation remains safe after a specified period (usually every 5 years in rented properties).
- Change of Occupancy: When a property is being rented or sold, an EICR may be required to ensure the installation is safe for new tenants or owners.
- Following Damage or Alterations: If the installation has been affected by external damage (e.g., fire, flooding) or significant changes have been made (e.g., new circuits added), an EICR is necessary to confirm it meets current safety standards.
Section C: Details of the Installation
This part of the EICR example provides specific details about the electrical installation under inspection. It includes information such as:
- Type of property (residential, commercial, etc.)
- Age of the installation
- Date of the previous EICR
- Any known limitations that might affect the scope of the report
Section D: Extent and Limitations of the Inspection
An EICR example would also include a section outlining the extent and limitations of the inspection. This part explains what parts of the electrical installation were inspected and any limitations that were present, such as inaccessible areas or safety concerns.
Section E: Summary of the Condition of the Installation
In this EICR example, the summary section provides a concise overview of the overall condition of the electrical installation and an overall assessment outcome: either Satisfactory or Unsatisfactory.
Section F: Recommendations
The Next Inspection Recommendation section of the EICR specifies when the electrical installation should be inspected again to ensure it remains in a safe and compliant condition. This is an important part of the report, as regular inspections are crucial for maintaining the safety of the electrical system over time.
The recommended interval for the next inspection is typically based on:
- The type and condition of the installation
- The environment in which it is used (e.g., domestic, commercial, industrial)
- Regulatory requirements or guidelines (e.g., rented properties usually require inspections every 5 years)
This section provides a clear date or time frame, ensuring property owners are aware of their responsibilities to maintain electrical safety by scheduling future EICRs within the recommended period.
Section G: Declaration
The Declaration section of the EICR is a formal statement made by the qualified electrician or contractor who conducted the inspection. It certifies that the inspection has been carried out in accordance with the relevant standards and regulations, specifically BS 7671 (the IET Wiring Regulations). This section is crucial as it confirms the accuracy and reliability of the findings in the report.
It typically includes:
- The name and signature of the inspector
- The date the inspection was completed
- Confirmation that the report reflects a true and accurate assessment of the installation’s condition
The declaration ensures accountability and provides assurance that the report is conducted by a competent professional following industry standards.
To find out more about Qualified Electrical Inspector check out my detailed article here.
Sections H-J: Supply Characteristics and Earthing Arrangements
An important section in any EICR example, this part provides technical details about the electrical supply and earthing arrangements. It includes information such as voltage, number of phases, type of earthing system (e.g., TN-S, TN-C-S, TT), and maximum demand.
Section K: Observations and Recommendations for Actions to be Taken
Every EICR example should clearly list all observations made during the inspection. Each observation is categorised by its severity to help prioritise actions:
- C1 (Danger Present): Immediate remedial action required.
- C2 (Potentially Dangerous): Urgent remedial action needed.
- C3 (Improvement Recommended): Actions recommended but not necessary for immediate safety.
- FI (Further Investigation Required): Further investigation is required without delay.
For more information on classification codes, refer to my dedicated article: EICR Codes Explained- Understanding C1, C2, C3, FI.
Section L: Schedule of Test Results
In an EICR example, the schedule of test results is one of the most technical parts. It documents the results of tests performed on the circuits to evaluate their safety and functionality. These tests include:
- Continuity of protective conductors
- Insulation resistance
- Polarity
- Earth fault loop impedance
- RCD (Residual Current Device) testing
Section N: Schedule of Inspections
This section of the EICR example is a detailed checklist of various components of the electrical system that have been inspected. Each item is marked as satisfactory, not applicable, or requiring attention, ensuring all parts of the installation, from distribution boards to wiring accessories, are thoroughly assessed.
Guidance for Recipients
The Guidance for Recipients section provides important instructions and advice for the person receiving the EICR. It explains how to interpret the report’s findings and what actions are required based on the observations and recommendations. This section is crucial for ensuring that property owners or managers fully understand their obligations and the next steps for maintaining electrical safety.
Key points typically include:
- An explanation of the codes used in the report (C1, C2, C3, FI) and the urgency of the actions they represent.
- Information on how to address any issues highlighted, including recommendations for remedial work.
- Guidance on the legal and safety responsibilities of the recipient, especially in rental properties or workplaces.
This section ensures that the recipient has a clear understanding of the report and the importance of acting on any identified issues to ensure ongoing safety and compliance.
Electrical Test Instrument Calibration Certificate
At Testar Ltd, we believe in providing complete transparency and the highest standards of service. That’s why we always include a copy of the calibration certificate for the testing equipment used during your EICR. This certificate verifies that the tester has been recently calibrated and is operating accurately, ensuring that all results recorded in your EICR are reliable and precise.
By providing this extra documentation, we aim to give our clients full assurance that their electrical systems have been thoroughly and accurately assessed.
Why Understanding an EICR Example is Important
Reviewing an EICR example helps you understand the importance of regular electrical inspections. An EICR is not just a formality—it’s a critical document that ensures the safety of your property’s electrical systems. Regular EICRs help identify potential hazards before they become serious risks, providing peace of mind and safeguarding your property and its occupants.
Conclusion
If you’re looking to understand more about EICRs or need an EICR example for reference, this guide should help clarify what you can expect. Remember, ensuring your electrical installation is safe and up to standard is not just about compliance; it’s about safety and peace of mind. If you have any questions or would like to schedule an inspection, don’t hesitate to contact us. Your safety is our priority!
Book Your EICR Inspection Online Today!
Ready to ensure your property is safe and compliant with a professional EICR inspection? We’ve made the process simple and convenient for you. With our online booking system, you can easily schedule an EICR inspection directly from our website. Just enter your details, choose a suitable date, and complete your payment securely through Stripe. It’s that easy!